Skip to content
Drawings and ring binders on a desk above the Riyadh skyline

Standards

The codes we design and test to: NFPA 10, 13, 14, 20, 25, 72, 96 and 2001, SBC 801 and Saudi Civil Defense requirements.

In plain words

What each one covers, and where we apply it

A short guide for anyone reading a specification or a certificate. It explains what each standard is about. It is not engineering advice for a particular building: for that, send us the site details.

  • NFPA 10

    Portable fire extinguishers

    Selecting, placing, inspecting, maintaining and testing portable extinguishers.

    Where we apply itExtinguishers in every kind of building, from a warehouse to a corner shop.

  • NFPA 13

    Installation of sprinkler systems

    How a sprinkler system is designed and installed for the hazard it protects.

    Where we apply itSprinkler systems, including pre-action, hydraulically calculated.

  • NFPA 14

    Standpipe and hose systems

    The risers and hose connections that bring fire water to each floor.

    Where we apply itStandpipes and hose reels, with witnessed pressure and flow tests.

  • NFPA 20

    Stationary fire pumps

    The installation of the pumps that supply fire water to a building.

    Where we apply itFire pumps, tanks and control panels, with the associated utilities.

  • NFPA 25

    Inspection, testing and maintenance of water-based systems

    What has to be inspected, tested and maintained once a water-based system is in service.

    Where we apply itThe backbone of our maintenance contracts, with deficiencies listed, priced and closed out.

  • NFPA 72

    Fire alarm and signaling

    Detection, alarm and signaling systems, and how they are tested and kept in service.

    Where we apply itDetection and alarm systems, inspected and tested under an annual maintenance contract.

  • NFPA 96

    Commercial cooking operations

    Ventilation control and fire protection for commercial kitchens.

    Where we apply itKitchen protection: wet chemical suppression for hoods, commissioned with records.

  • NFPA 2001

    Clean agent systems

    Gaseous fire suppression that leaves no residue, for rooms where water would do harm.

    Where we apply itGas suppression for electrical rooms, control rooms and data centres.

  • SBC 801

    Saudi Building Code, fire protection

    The fire protection part of the Saudi Building Code.

    Where we apply itEvery design and every test, alongside the NFPA standard that applies.

  • Civil Defense

    Saudi Civil Defense requirements

    What the authority requires before it approves a design, and at each inspection after that.

    Where we apply itDesigned to from the first drawing, with a pre-inspection record signed by our engineer.

Get in touch

Send us the tender documents.

We read the fire scope and come back with clarifications before we price. Tell us about the project here and it goes straight to our sales engineers, who answer within one working day.

Office
Riyadh, Saudi Arabia

An email address or a phone number, so we can answer you.